Get off work;No need to watch;Maximum daily (8 hours) throughput: 96
¥ 400000.00
Service hotline:0816-2277909
1、Follow conventional and international analysis principles
2、Analyze and measure crude fiber, acid washing fiber, neutral washing fiber and acid washing lignin
3、Automatic injection solutions and water needed
4、Up to 24 samples can be measured at a time
5、High repeatability and accurate measurement results
6、Microcomputer automatic control
7、Safe alloy steel sealed digestion cavity
8、Get off work,no need to watch
9、Maximum daily (8 hours) throughput: 96
Analysis of the current domestic crude fiber mostly used acid Digestion, filtration method and with the transfer of the crucible. The process is not only labor intensive, time consuming, and because the process of boiling acid-base fire control properly, it is easy to overflow, resulting residue losses, especially when alkali treatment, more likely to cause the operator to potential security threats. In addition, when transferring the residue to the crucible, it is easy to cause suction filtration difficulty or leakage. When using ANKOM's original filter bag technology to analyze the crude fiber, suction filtration is omitted, and it can be measured in batches.
High accuracy and precision ANKOM adopts advanced American filter bag technology and adopts a fully automatic test procedure, so it can eliminate many factors that affect the accuracy and precision of fiber analysis results, greatly ensuring ≤±0.5% accuracy of analysis. The unique three-dimensional structure of ANKOM filter bags can ensure that the analysis results of the tested samples have a high repeatability (±0.5%). The operator only needs to follow the operating rules to obtain accurate analysis results at one time.
High efficiency and low cost The ANKOM fiber analyzer has a high cost performance, and the main thing is that the operator does not need to be specially guarded, and can perform other analysis work at the same time. Skilled operators can measure 4 batches of fiber samples a day, a total of 96, and work efficiency can be greatly improved, saving a lot of labor.
High degree of safety and automation Due to the use of fully automatic measurement procedures and solvent or hot water injection systems, all heating, agitation, rinsing and waste liquid discharge are automated, and the ANKOM A2000i fiber analyzer greatly eliminates labor Danger of direct handling of hot chemical reagents. At the same time, the safety protection device also monitors every step of the experiment at all times. For example, when the solution is used up and the water is suddenly stopped, the instrument control system will immediately stop the heating and stirring work and emit a sound and light warning. At the end of the analysis process, the instrument sounds a short notice, and the entire analysis process is very intelligent and safe.
The analysis results are accurate. A large number of joint laboratory comparative analysis data show that the filter bag analysis technology is suitable for various sample tests specified by AOCS (American Society of Oil Chemists), and the analysis results can be consistent with the results of traditional methods (including China's GB method)
Instrument parameters | |
Filter bag structure | 25 μm /10μm pore three-dimensional structure |
Sampling volume/bag | 0.5~1.0 g |
Cellulose range | 0%~100% |
Time for each measurement | Time for batch processing: 60-120 minutes (including heating process) |
Sample batch capacity | 1~24 |
Daily processing capacity (at 8 hours of operation) | Up to 96 crude fibers or 144 (neutral washing fibers or acid washing fibers) |
Standard deviation of results | ≤±0.5% |
Repeatability accuracy | ≤±0.5% |
Degree of intelligence | Fully automatic precise heating, constant temperature, vortex agitation, automatic injection/removal of solvent (digestion), automatic leaching/removal of waste liquid |
Program settings | Automatic program for crude fiber, neutral detergent fiber, acid detergent fiber |
Processing temperature range | Room temperature~100℃ |
Temperature control accuracy | ±0.1℃ |
safety | Experimental equipment without dangerous glass tube material. Multi-point security monitoring. Sharp temperature and pressure detector, automatic shutdown temperature: 115℃. Sample digestion, rinsing, filtration and other processes are carried out in a closed state, and there is no discomfort caused by irritating odor dissipation. Alloy cylinder block, closed environment, work off-hand |
Environmental requirements | Routine laboratory without fume hood |
Main materials | The stainless steel structure of the whole machine, the reaction cylinder is thick stainless steel, high temperature and high pressure resistance and chemical corrosion resistance |
Instrument specifications | |
Dimensions (W × D × H) | 18''×14''×23'' |
Operating Voltage | 220-240 V,50-60 Hz |
Instrument weight | About 40 kg |
Machine imported | High degree of fit in use |
This parameter is part of the parameter, if the parameter is changed, without notice

Joint laboratory data AOCS FIG bag coarse fibers (cited: AOCS Procedure No.BA 6a-5)